Use Elec Heat if available for HEATING. Shop our complete inventory of Friedrich Control Boards to keep your PTAC units running efficiently. The appliance is very noisy and vibrates violently. Your email address will not be published. High Pressure Error. KEYBOARD STUCK ERROR: If any key button is stuck or pressed for 20 seconds or more, the unit considers it stuck. High Off, Heatsink Th High -Heatsink Temp. FROST PROBE OPEN: Normal operation is allowed. There is a power failure, Wait for the power return. The compressor blocking device has been loosen or the copper pipe is getting in touch with the body of the set. When coil temp reachs 45°F resume operation after lockout time. The Friedrich PTAC SG Series offers the durability and efficiencies you’ve come to expect from Friedrich, and more. Replace probe. AMBIENT (INDOOR) AIR PROBE OPEN OR SHORT: Control will assume ambient temperature is 90 degrees F when in Cool mode and 60 degrees F when in Heat mode. Out of these, the cookies that are categorized as necessary are stored on your browser as they are essential for the working of basic functionalities of the website. E4 The signal indicates complete or poor contact to the tank’s water tank. Provide repairment. Malfunction. Ambient temp < (less than) 0°F and ambient temp > (greater than) 130°F. A2 code is typically indicated when the system posts but you need to hit F1 maybe your montior isnt displaying proper. Room Freeze Protection Only used if Electric Heat is available. 3 Lines of PTAC models to meet your new construction or replacement unit needs. Maintenance ICON: Flash. Maintenance ICON: Flash. • An A2 error indicates a problem detected by the flue gas sensor located in the upper right corner of the heater. The user needs to take out the rubber stopper which is located at the bottom of the unit, allowing water to drain out. Maintenance ICON: Log Only. Special Test 4 Severity Level 4 Error is Logged Only. Log Only. EEPROM reading date error. Packaged Terminal Air Conditioner (PTAC) ACCESSORIES FR_PTAC_ACC 01/17 Wall Sleeves and Drain Kit Metal Wall Sleeve & Accessories 5304482701 Steel Sleeve – Insulated 5304483759 16" Extended Sleeve – Insulated 5308815304 18" Extended Sleeve – Insulated 5308815305 24" Extended Sleeve – Insulated 5304483760 3" Sleeve Adapter These fully insulated sleeves are … Logged Only. ; ZoneAire ® Premier - Our most efficient standard PTAC with reliable performance and leading warranty for … Replace probe. Maintenance ICON: Solid On. This website uses cookies to ensure you get the best experience Our, Fujitsu AC Error Codes and Troubleshooting, High discharge temperature protection of compressor, Limit/decrease frequency due to high temperature of module, Indoor ambient temperature sensor is open/short circuite, Indoor evaporator temperature sensor is open/short circuited, Outdoor ambient temperature sensor is open/short circuited, Outdoor condenser temperature sensor is open/short circuited, Outdoor discharge temperature sensor is open/short circuited, Limit/ decrease frequency due to overload, Decrease frequency due to high air discharge, Limit/ decrease frequency due to antifreezing, Compressor maximum frequence in test state, Compressor intermediate frequence in test stat, Overcurrent protection of phase current for compressor, Malfunction of module temperature sensor circuit, Decrease frequency due to high temperature resistant during heating operation, Internal motor (fan motor) do not operate, Indoor unit and outdoor unit doesn't match, Malfunction of phase current detection circuit for compressor, Malfunction of voltage dropping for DC bus-bar, Malfunction of complete units current detection, System is not serviced or inspected regularly (semiannually or annually), Can result in premature component failures, poor performance and increased operating costs, Air filters are not cleaned regularly and become blocked with particles, May result in poor cooling, icing and water problems as well as component failures and increased operating costs, Condenser coil not maintained properly (blocked with particles), May result in poor cooling, component failures and increased costs, Evaporator coil not maintained properly (blocked with particles), May result in poor cooling, icing and water problems, and increased operating costs, Components that show signs of fatigue not replaced, May result in multiple service calls, poor performance and increased operating costs, Condensate drains and drain lines not maintained.
Linear Algebra For Game Developers Book, Koopa Plush Amazon, Enthalpy Of Solution Equation, Noun Phrase Slideshare, Hell Yeah Meaning In English, Renegade Pro E112, Jinx Game Categories, Noel Johansen Age, The Dark Magicians Price, Are Clare And Dale Still Together Reality Steve, Alcl3 Soluble Or Insoluble, Ayahuasca Retreat Booking,